Manual
MAX15301 PMBus Command Set User’s Guide 
Rev 1    Page 36 of 53 
Device Identification Commands 
CAPABILITY 
Reference: 
Standard Command 
Lockable: 
N/A 
Command Code: 
0x19 
Format: 
Bit field 
Data Bytes: 
1 
Units: 
N/A 
Transfer: 
Read Byte 
Factory Value: 
0xA0 
Description/Notes: 
See Section 11.12 of the PMBus Specification Part II. 
PMBUS_REVISION 
Reference: 
Standard Command 
Lockable: 
N/A 
Command Code: 
0x98 
Format: 
Bit field 
Data Bytes: 
1 
Units: 
N/A 
Transfer: 
Read Byte 
Factory Value: 
0x42 (see Description) 
Description/Notes: 
See Section 22.1 of the PMBus Specification Part II. 
Note that the Maxim interpretation of the specification is to omit bit #4, placing the Part I Revision 
level in bits [7:5] and the Part II Revision level in bits [3:0]. 
Bits [7:5] describe the PMBus specification Part I revision level as follows: 
000  Revision 1.0 
001  Revision 1.1 
010  Revision 1.2 
Bit [4] is unused and is set to zero. 
Bits [3:0] describe the PMBus specification Part II revision level as follows: 
0000  Revision 1.0 
0001  Revision 1.1 
0010  Revision 1.2 
MFR_ID 
Reference: 
Standard Command 
Lockable: 
Yes 
Command Code: 
0x99 
Format: 
ASCII string 
Data Bytes: 
8 
Units: 
N/A 
Transfer: 
Read/Write Block 
Factory Value: 
Null string 
Description/Notes: 
See Section 22.2.1 of the PMBus Specification Part II. 
Note that the MAX15301 implements MFR_ID as a fixed-width string, not as part of a shared memory 
space. 