MAX15301 PMBus Command Set User’s Guide 
Rev 1    Page 30 of 53 
Telemetry Commands 
READ_VIN 
Reference: 
Standard Command 
Lockable: 
N/A 
Command Code: 
0x88 
Format: 
Linear 
Data Bytes: 
2 
Units: 
V 
Transfer: 
Read Word 
Factory Value: 
N/A 
Description/Notes: 
See Section 18.1 of the PMBus Specification Part II. 
The MAX15301 has 12-bit  measurement  resolution for input voltage to a maximum value of about 
14.75V. 
READ_VOUT 
Reference: 
Standard Command 
Lockable: 
N/A 
Command Code: 
0x8B 
Format: 
Unsigned integer mantissa 
Data Bytes: 
2 
Units: 
V 
Transfer: 
Read Word 
Factory Value: 
N/A 
Description/Notes: 
See Section 18.4 of the PMBus Specification Part II. 
The value of VOUT_TRIM  is not  subtracted from READ_VOUT, so non-zero VOUT_TRIM values will 
result in a difference between VOUT_COMMAND and READ_VOUT. 
The value of VOUT_CAL_OFFSET is subtracted from READ_VOUT, so VOUT_CAL_OFFSET values never 
result in a difference between VOUT_COMMAND and READ_VOUT. 
READ_IOUT 
Reference: 
Standard Command 
Lockable: 
N/A 
Command Code: 
0x8C 
Format: 
Linear 
Data Bytes: 
2 
Units: 
A 
Transfer: 
Read Word 
Factory Value: 
N/A 
Description/Notes: 
See Section 18.5 of the PMBus Specification Part II. 
The MAX15301 has 8-bit measurement resolution for load current over a variable, symmetric bipolar 
range of inductor DCR voltage. READ_IOUT data is filtered and decimated, so reported load current 
may display greater than 8-bit resolution. 
READ_IOUT must be calibrated by means of IOUT_CAL_GAIN  and IOUT_CAL_OFFSET
  to achieve 
accurate results. 
The value of READ_IOUT is temperature compensated for sense-element resistance change according 
to READ_TEMPERATURE_2
 and the resistive temperature coefficient value in the third data byte of 
EXT_TEMP_CAL. 