MAX15301 PMBus Command Set User’s Guide 
Rev 1    Page 28 of 53 
Unit Status Commands 
STATUS_BYTE 
Reference: 
Standard Command 
Lockable: 
N/A 
Command Code: 
0x78 
Format: 
Bit field 
Data Bytes: 
1 
Units: 
N/A 
Transfer: 
Read Byte 
Factory Value: 
N/A 
Description/Notes: 
See Section 17.1 of the PMBus Specification Part II. 
STATUS_WORD 
Reference: 
Standard Command 
Lockable: 
N/A 
Command Code: 
0x79 
Format: 
Bit field 
Data Bytes: 
2 
Units: 
N/A 
Transfer: 
Read Word 
Factory Value: 
N/A 
Description/Notes: 
See Section 17.2 of the PMBus Specification Part II. 
Bit #2 of the STATUS_WORD low byte is not implemented in the MAX15301 because there are no 
relevant fan-related commands. 
STATUS_VOUT 
Reference: 
Standard Command 
Lockable: 
N/A 
Command Code: 
0x7A 
Format: 
Bit field 
Data Bytes: 
1 
Units: 
N/A 
Transfer: 
Read Byte 
Factory Value: 
N/A 
Description/Notes: 
See Section 17.3 of the PMBus Specification Part II. 
Bits #5 and #6 of STATUS_VOUT are not implemented in the MAX15301 because the 
VOUT_UV_WARNING and VOUT_OV_WARNING commands are not supported. 
Bit #1 is not implemented in the MAX15301 because the TOFF_MAX_WARNING is not supported. 
STATUS_IOUT 
Reference: 
Standard Command 
Lockable: 
N/A 
Command Code: 
0x7B 
Format: 
Bit field 
Data Bytes: 
1 
Units: 
N/A 
Transfer: 
Read Byte 
Factory Value: 
N/A 
Description/Notes: 
See Section 17.4 of the PMBus Specification Part II. 
Bits #6, #4, #2, #1, and #0 
are not implemented in the MAX15301 because the corresponding fault 
commands are not supported. 