VIN_UV_FAULT_RESPONSE 
  restart according to bits [5:3]. 
11  Stop regulating immediately, and then restart as soon as possible after the fault 
  condition abates. (Default setting) 
Bits [5:3] determine the number of retry attempts. The MAX15301 supports only a subset of the full 
PMBus functionality for this portion of the command: 
000-110  No attempt is made to restart after a fault shutdown. (Default setting) 
111  Attempt to restart continuously until commanded off, or until another fault 
  condition causes the unit to shut down. 
Bits [2:0] determine the fault-tolerance or retry-delay timing. Each binary value in bits [2:0] 
corresponds to a multiple of 100ms, up to a possible maximum of 111
bin
 = 700ms. A value of 000
bin
will cause the MAX15301 to use the minimum possible timing value, typically about 30-40ms. (The 
default timing for input undervoltage faults is 000
bin
.) 