MAX15301 PMBus Command Set User’s Guide 
Rev 1    Page 25 of 53 
OT_WARN_LIMIT 
Reference: 
Standard Command 
Lockable: 
Yes 
Command Code: 
0x51 
Format: 
Linear 
Data Bytes: 
2 
Units: 
°C 
Transfer: 
Read/Write Word 
Factory Value: 
0xEAF8 (95°C) 
Description/Notes: 
See Section 15.19 of the PMBus Specification Part II. 
The MAX15301 has an internal temperature signal and can also measure temperature at an external 
location, using a diode junction. 
The OT_WARN_LIMIT applies to the external temperature signal, if a valid sensor is detected during 
initialization. If no external sensor is detected, the OT_WARN
_LIMIT applies to the internal 
temperature signal instead. 
Overtemperature fault hysteresis is achieved in the MAX15301 by using the OT_WARN_LIMIT as the 
“fault cleared” threshold for OT_FAULT_LIMIT. For this 
reason, it is important to always set 
OT_WARN_LIMIT below OT_FAULT_LIMIT. 
VIN_OV_FAULT_LIMIT 
Reference: 
Standard Command 
Lockable: 
Yes 
Command Code: 
0x55 
Format: 
Linear 
Data Bytes: 
2 
Units: 
V 
Transfer: 
Read/Write Word 
Factory Value: 
0xD380 (14V) 
Description/Notes: 
See Section 15.23 of the PMBus Specification Part II. 
The MAX15301 hardware has 8-bit resolution for the input overvoltage fault limit, to a maximum 
value of ≈14.75V. 
The desired value of VIN_OV_FAULT_LIMIT is retained in memory, regardless limitations imposed by 
the 8-bit fault limit resolution, but the read-back value is based on actual hardware register settings. 
VIN_OV_FAULT_RESPONSE 
Reference: 
Standard Command 
Lockable: 
Yes 
Command Code: 
0x56 
Format: 
Bit field 
Data Bytes: 
1 
Units: 
N/A 
Transfer: 
Read/Write Byte 
Factory Value: 
0xC0 (Shut down, restart when fault 
abates) 
Description/Notes: 
See Sections 10.5.1 and 15.24 of the PMBus Specification Part II. 
Note that the MAX15301 does not support finite, non-zero restart-attempt counts. (Continuous 
restart attempts are supported.) 
The VIN_OV_FAULT_RESPONSE command data comprises three bit-fields: 
Bits [7:6] determine the basic fault-response mode. The MAX15301 supports the following modes: 
00  Ignore the fault condition. 
01  Continue operating and wait for the fault to abate for time specified in bits [2:0]. If the 
  fault does not abate, shutdown and attempt to restart according to bits [5:3]. 