MAX15301 PMBus Command Set User’s Guide
Rev 1 Page 19 of 53
TOFF_FALL
Reference:
Lockable:
Yes
Command Code:
Format:
Linear
Data Bytes:
Units:
ms
Transfer:
Factory Value:
0xCA80 (see Description)
Description/Notes:
See Section 16.6 of the PMBus Specification Part II.
The TOFF_FALL command sets the ramp-down time from regulation at VOUT_COMMAND to 0V. The
nominal factory value is 5ms.
The MAX15301 achieves shutdown dV
OUT
/dt control by decrementing the loop setpoint by one 12-bit
step every time a certain number of ramp-controller clock cycles have elapsed in an 8-bit counter.
This results in a setpoint that decreases at a controlled rate, in turn creating a constant dV
OUT
/dt
during shutdown.
Because the MAX15301 must calculate the ramp co
ntrol timer setting based upon the value of
VOUT_COMMAND, the possible range and resolution of TOFF_FALL will vary significantly.
The desired value of TOFF_FALL is retained in memory, regardless of ramp-timer limitations, but the
read-back value is based on actual hardware register settings.