Manual
MAX15301 PMBus Command Set User’s Guide 
Rev 1    Page 19 of 53 
TOFF_FALL 
Reference: 
Standard Command 
Lockable: 
Yes 
Command Code: 
0x65 
Format: 
Linear 
Data Bytes: 
2 
Units: 
ms 
Transfer: 
Read/Write Word 
Factory Value: 
0xCA80 (see Description) 
Description/Notes: 
See Section 16.6 of the PMBus Specification Part II. 
The TOFF_FALL command sets the ramp-down time from regulation at VOUT_COMMAND to 0V. The 
nominal factory value is 5ms. 
The MAX15301 achieves shutdown dV
OUT
/dt control by decrementing the loop setpoint by one 12-bit 
step every time a certain number of ramp-controller clock  cycles  have elapsed in an 8-bit counter. 
This results in a setpoint  that decreases at a controlled rate, in turn creating a constant dV
OUT
/dt 
during shutdown. 
Because the MAX15301 must calculate the ramp co
ntrol timer setting based upon the value of 
VOUT_COMMAND, the possible range and resolution of TOFF_FALL will vary significantly. 
The desired value of TOFF_FALL is retained in memory, regardless of ramp-timer limitations, but the 
read-back value is based on actual hardware register settings. 