Manual
MAX15301 PMBus Command Set User’s Guide 
Rev 1    Page 18 of 53 
TON_RISE 
Reference: 
Standard Command 
Lockable: 
Yes 
Command Code: 
0x61 
Format: 
Linear 
Data Bytes: 
2 
Units: 
ms 
Transfer: 
Read/Write Word 
Factory Value: 
0xCA80 (see Description) 
Description/Notes: 
See Section 16.2 of the PMBus Specification Part II. 
The TON_RISE command sets the ramp-up  time from 0V  to regulation at VOUT_COMMAND.  The 
nominal factory value is 5ms. 
The MAX15301 achieves startup dV
OUT
/dt control by incrementing the loop setpoint by one 12-bit 
step every time a certain number of ramp-controller clock  cycles  have elapsed in an 8-bit counter. 
This results in a setpoint that increases at a controlled rate, in turn creating a constant dV
OUT
/dt 
during startup. 
Because the MAX15301 must calculate the ramp control timer setting based upon the value of 
VOUT_COMMAND, the possible range and resolution of TON_RISE will vary significantly. 
The desired value of TON_RISE is retained in memory, regardless of ramp-timer limitations, but the 
read-back value is based on actual hardware register settings. 
TOFF_DELAY 
Reference: 
Standard Command 
Lockable: 
Yes 
Command Code: 
0x64 
Format: 
Linear 
Data Bytes: 
2 
Units: 
ms 
Transfer: 
Read/Write Word 
Factory Value: 
0xBA00 (see Description) 
Description/Notes: 
See Section 16.5 of the PMBus Specification Part II. 
The TOFF_DELAY command sets the delay time between loss of enable condition and the beginning 
of the output ramp-down. The nominal factory value is 1ms. 
An 8-bit timer with approximately 570μs resolution allows for delay times from 0ms to ≈145ms. 










