Manual
MAX15301 PMBus Command Set User’s Guide 
Rev 1    Page 17 of 53 
POWER_GOOD_OFF 
Reference: 
Standard Command 
Lockable: 
Yes 
Command Code: 
0x5F 
Format: 
Unsigned integer mantissa 
Data Bytes: 
2 
Units: 
V 
Transfer: 
Read/Write Word 
Factory Value: 
0x0F99 (see Description) 
Description/Notes: 
See Section 15.32.2 of the PMBus Specification Part II. 
POWER_GOOD_OFF mantissa data sent to and from the MAX15301 must be divided by 4096 to 
determine the actual voltage value, according to the fixed value of VOUT_MODE
. 
In the MAX15301, there are seven possible output voltage ranges based on seven corresponding 
internal feedback divider taps. The MAX15301 hardware has 8-bit resolution for the power-good 
threshold within each of these seven ranges. 
The desired value of POWER_GOOD_OFF is retained in memory, regardless of limitations imposed by 
the feedback divider range and the 8-bit fault limit resolution, but the read-back value is based on 
actual hardware register settings. 
The factory value of 0x0F99 (0.980V) will be overridden during initialization to 
VOUT_COMMAND x 0.93, unless a specific value has been written to the User Store. 
TON_DELAY 
Reference: 
Standard Command 
Lockable: 
Yes 
Command Code: 
0x60 
Format: 
Linear 
Data Bytes: 
2 
Units: 
ms 
Transfer: 
Read/Write Word 
Factory Value: 
0xCA80 (see Description) 
Description/Notes: 
See Section 16.1 of the PMBus Specification Part II. 
The TON_DELAY command sets the delay time between a valid enable condition and the beginning of 
the output ramp to regulation at VOUT_COMMAND
. The nominal factory value is 5ms. 
An 8-bit timer with approximately 570μs resolution allows for delay times from ≈1ms to ≈145ms. 