Manual
MAX15301 PMBus Command Set User’s Guide 
Rev 1    Page 14 of 53 
VOUT_DROOP 
accurate adaptive voltage positioning results with the VOUT_DROOP command. 
Note that VOUT_DROOP can accept negative resistance values, allowing a user to compensation for 
resistive losses between the output voltage remote sense point and the load, if desired. (Setting 
VOUT_DROOP to a negative value will case output voltage to rise with increasing load.) 
Wait  at  least  500μs  for  execution  after  sending 
the VOUT_DROOP command before sending 
additional PMBus commands. 










