Datasheet

MAX15036/MAX15037
2.2MHz, 3A Buck or Boost Converters
with an Integrated High-Side Switch
8 _______________________________________________________________________________________
Pin Description
PIN NAME FUNCTION
1, 2 DRAIN
Internal Power MOSFET Drain Connection. Buck converter operation—use the MOSFET as a high-side switch
and connect DRAIN to the input supply. Boost converter operation (MAX15036 only)—use the MOSFET as a
low-side switch and connect DRAIN to the inductor and diode junction.
3 COMP
Transconductance Error Amplifier Output. Connect a compensation network from COMP to SGND or from
COMP to FB to SGND (see the Compensation section).
4 FB Feedback Input. Connect a resistive divider from the output to FB to SGND to set the output voltage.
5 OSC
Switching Frequency Set Input. Connect a resistor R
OSC
from OSC to SGND to set the switching frequency.
When using external synchronization, program R
OSC
so that (0.8 x f
SYNC
) f
SW
≤ (1.2 x f
SYNC
). R
OSC
is still
required when external synchronization is used.
6 BYPASS Reference Bypass Connection. Bypass to SGND with a 0.22μF or greater ceramic capacitor.
7V+
Input Supply Voltage. V+ can range from 5.5V to 23V. Connect V+ and V
L
together for 4.5V to 5.5V input
operation. Bypass V+ to SGND with a minimum of 0.1μF ceramic capacitor.
8V
L
Internal Regulator Output. Bypass V
L
to SGND with a 4.7μF ceramic capacitor and to PGND with a 0.1μF
ceramic capacitor. Connect V+ to V
L
for 4.5V to 5.5V operation.
CKO
Clock Output (MAX15036 Only). CKO is an output with the same frequency as the converter’s switching
frequency and 115° out-of-phase. CKO is used to synchronize the MAX15036 to other MAX15036/MAX15037s.
9
DL
Low-Side Synchronous Rectifier Driver (MAX15037 Only). DL sources 0.7A and sinks 1A to quickly turn on and
off the external synchronous rectifier MOSFET.
10 SGND Signal Ground
11 PGND
Power Ground. Connect the rectifier diode’s anode, the input capacitor negative terminal, the output capacitor
negative terminal, and V
L
bypass capacitor negative terminal to PGND.
12 SOURCE
Internal Power MOSFET Source Connection. Buck converter operation—connect SOURCE to the switched side
of the inductor as shown in Figure 5. Boost converter operation (MAX15036 only)—connect SOURCE to PGND.
13 SYNC
External Synchronization Input. Connect SYNC to an external logic-level clock to synchronize the MAX15036/
MAX15037. Connect SYNC to SGND when not used.
RESET
Open-Drain Active-Low Reset Output (MAX15036 Only). RESET remains low while the converter’s output is
below 92.5% of V
OUT
’s nominal set point. When V
OUT
rises above 92.5% of its nominal set point, RESET goes
high after the reset timeout period of 200ms (typ).
14
PGOOD
Open-Drain Power-Good Output (MAX15037 Only). PGOOD remains low while the output is below 92.5% of its
nominal set point.
15 BST/VDD
Internal MOSFET Driver Supply Input. Buck converter operation—bootstrap flying capacitor connection.
Connect BST/VDD to an external ceramic capacitor and diode (see Figure 5). Boost converter operation
(MAX15036 only)—driver bypass capacitor connection. Connect a low-ESR 0.1μF ceramic capacitor from
BST/VDD to PGND.
16 EN
Enable Input. A logic-low turns off the converter. A logic-high turns on the device. Connect EN to V
L
for an
always-on application.
EP Exposed Pad. Connect to SGND. Solder EP to SGND to enhance thermal dissipation.