Datasheet
MAX14820
IO-Link Device Transceiver
7Maxim Integrated
AC ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= 18V to 36V, V
L
= 2.3V to 5.5V, V
GND
= 0V; all logic inputs at V
L
or GND; T
A
= -40NC to +85NC, unless otherwise noted. Typical
values are at V
CC
= 24V, V
L
= 3.3V, and T
A
= +25NC, unless otherwise noted.) (Note 2)
Note 2: All devices are 100% production tested at T
A
= +25NC. Limits over the operating temperature range are guaranteed by
design.
Note 3: UV is an open-drain output. Connect UV to a voltage less than 5.5V through an external pullup resistor.
Note 4: Disable time measurements are load dependent.
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
SPI TIMING (CS, SCLK, SDI, SDO) (Figure 6)
SCLK Clock Period t
CH+CL
83.3 ns
SCLK Pulse-Width High t
CH
41.65 ns
SCLK Pulse-Width Low t
CL
41.65 ns
CS Fall to SCLK Rise Time
t
CSS
20 ns
SCLK Rise to CS Rise Hold Time
t
CSH
20 ns
SDI Hold Time t
DH
10 ns
SDI Setup Time t
DS
10 ns
Output Data Propagation Delay t
DO
32 ns
SDO Rise and Fall Times t
FT
20 ns
Minimum CS Pulse
t
CSW
76.8 ns










