Note 2: All devices are 100% production tested at T
A
= +25NC, unless otherwise noted. Limits over the -40NC to +85NC operating
temperature range are guaranteed by design.
Note 3: Turn-on time and turn-off time are defined as the difference in the time between when the output voltage crosses 10% and
90% of the final output voltage.
Note 4: Input current source can support voltage up to +40V (absolute maximum). Current reaction time is defined as the settling
time of the output current after a fault event.
DC ELECTRICAL CHARACTERISTICS (continued)
(I
IN
= 50FA to 24mA, T
A
= -40NC to +85NC, R
LOAD
= 25I to 1kI, unless otherwise noted. Typical values are at I
IN
= 10mA, R
LOAD
= 250I, and T
A
= +25NC.) (Note 2)
Typical Operating Characteristics
(V
IN
= 24V, I
IN
= 10mA, R
LOAD
= 250I, unless otherwise noted. Typical values are at T
A
= +25NC.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
THERMAL PROTECTION
Thermal Shutdown +150
NC
Thermal-Shutdown Hysteresis 20
NC
QUIESCENT I
Q
vs. V
IN
MAX14626 toc01
V
IN
(V)
32
2820 248 12 164
10
20
30
40
50
60
70
80
90
100
0
03
6
NO LOAD
QUIESCENT I
Q
(µA)
QUIESCENT I
Q
vs. I
IN
MAX14626 toc02
I
IN
(mA)
QUIESCENT I
Q
(µA)
10
20
30
40
50
60
70
80
90
100
0
02
015105
R
L
= 250I
R
L
= 100I
958050 65-10 5 20 35-25
QUIESCENT I
Q
vs. TEMPERATURE
MAX14626 toc03
TEMPERATURE (°C)
QUIESCENT I
Q
(µA)
10
20
30
40
50
60
70
80
90
100
0
-40 110
I
IN
= 20mA
I
IN
= 10mA
I
IN
= 0mA
I