External Acquisition Mode (Mode 1)
The slowest maximum throughput rate is achieved with
the external acquisition method. SCLK controls the acqui-
sition of the analog signal in external acquisition mode,
facilitating precise control over when the analog signal is
captured. The internal clock controls the conversion of the
analog input voltage. The analog input sampling instant is
at the falling edge of the 16th SCLK (Figure 3).
For the external acquisition mode, CS must remain low
for the first 15 clock cycles and the rise on or after the
falling edge of the 16th SCLK cycle as shown in Figure 3.
For optimal performance, idle DIN and SCLK during the
conversion. With careful board layout, transitions at DIN
and SCLK during the conversion have a minimal impact
on the conversion result.
After the conversion is complete, SSTRB asserts high
and CS can be brought low to read the conversion result.
SSTRB returns low on the rising SCLK edge of the sub-
sequent start bit.
Internal Clock Mode (Mode 2)
In internal clock mode, the internal clock controls both
acquisition and conversion of the analog signal. The inter-
nal clock starts approximately 100ns to 400ns after the
falling edge of the eighth SCLK and has a rate of about
4.5MHz. The analog input sampling instant occurs at the
falling edge of the 11th internal clock signal (Figure 4).
For the internal clock mode, CS must remain low for the
first seven SCLK cycles and then rise on or after the fall-
ing edge of the eighth SCLK cycle. After the conversion
is complete, SSTRB asserts high and CS can be brought
low to read the conversion result. SSTRB returns low on
the rising SCLK edge of the subsequent start bit.
Reset (Mode 4)
As shown in Table 8, set M[2:0] = 100 to reset the
MAX1300/MAX1301 to its default conditions. The default
conditions are full power operation with each channel
configured for ±3 x V
REF
, bipolar, single-ended conver-
sions using external clock mode (mode 0).
Partial Power-Down Mode (Mode 6)
As shown in Table 8, when M[2:0] = 110, the device enters
partial power-down mode. In partial powerdown, all ana-
log portions of the device are powered down except for
the reference voltage generator and bias supplies.
To exit partial power-down, change the mode by issuing
one of the following mode-control bytes (see the Mode
Control section):
• External-Clock-Mode Control Byte
• External-Acquisition-Mode Control Byte
• Internal-Clock-Mode Control Byte
• Reset Byte
• Full Power-Down-Mode Control Byte
This prevents the MAX1300/MAX1301 from inadvertently
exiting partial power-down mode because of a CS glitch
in a noisy digital environment.
Full Power-Down Mode (Mode 7)
When M[2:0] = 111, the device enters full power-down
mode and the total supply current falls to 1μA (typ). In full
power-down, all analog portions of the device are powered
down. When using the internal reference, upon exiting full
power-down mode, allow 10ms for the internal reference
voltage to stabilize prior to initiating a conversion.
To exit full power-down, change the mode by issuing one
of the following mode-control bytes (see the Mode Control
section):
• External-Clock-Mode Control Byte
Table 8. Mode-Control Bits M[2:0]
M2 M1 M0 MODE
0 0 0 External Clock (DEFAULT)
0 0 1 External Acquisition
0 1 0 Internal Clock
0 1 1 Reserved
1 0 0 Reset
1 0 1 Reserved
1 1 0 Partial Power-Down
1 1 1 Full Power-Down
MAX1300/MAX1301 8- and 4-Channel, ±3 x V
REF
Multirange Inputs,
Serial 16-Bit ADCs