Datasheet

Table 4. Averaging Register*
Table 5. Reset Register
*See below for bit details.
BIT NAME BIT FUNCTION
7 (MSB) Set to 0 to select averaging register.
6 Set to 0 to select averaging register.
5 Set to 1 to select averaging register.
AVGON 4 Set to 1 to turn averaging on. Set to 0 to turn averaging off.
NAVG1 3 Congures the number of conversions for single-channel scans.
NAVG0 2 Congures the number of conversions for single-channel scans.
NSCAN1 1 Single-channel scan count. (Scan mode 10 only.)
NSCAN0 0 (LSB) Single-channel scan count. (Scan mode 10 only.)
AVGON NAVG1 NAVG0 FUNCTION
0 x x Performs one conversion for each requested result.
1 0 0 Performs four conversions and returns the average for each requested result.
1 0 1 Performs eight conversions and returns the average for each requested result.
1 1 0 Performs 16 conversions and returns the average for each requested result.
1 1 1 Performs 32 conversions and returns the average for each requested result.
NSCAN1 NSCAN0 FUNCTION (APPLIES ONLY IF SCAN MODE 10 IS SELECTED)
0 0 Scans channel N and returns four results.
0 1 Scans channel N and returns eight results.
1 0 Scans channel N and returns 12 results.
1 1 Scans channel N and returns 16 results.
BIT NAME BIT FUNCTION
7 (MSB) Set to 0 to select reset register.
6 Set to 0 to select reset register.
5 Set to 0 to select reset register.
4 Set to 1 to select reset register.
RESET 3 Set to 0 to reset all registers. Set to 1 to clear the FIFO only.
x 2 Reserved. Don’t care.
x 1 Reserved. Don’t care.
x 0 (LSB) Reserved. Don’t care.
MAX11626–MAX11629/
MAX11632/MAX11633
12-Bit, 300ksps ADCs
with FIFO and Internal Reference
www.maximintegrated.com
Maxim Integrated
16