Table 9. Programmable Conversion Rates
RATE[3:0]
CONTINUOUS DATA RATE, SCYCLE = 0
SCYCLE = 1 SINGLE-CYCLE
CONTINUOUS DATA RATE (sps)
SINC FILTER (sps)
0000 1.9 50
0001 3.9 62.5
0010 7.8 100
0011 15.6 125
0100 31.2 200
0101 62.5 250
0110 125 400
0111 250 500
1000 500 800
1001 1000 1000
1010 2000 1600
1011 4000 2000
1100 8000 3200
1101 16000 4000
1110 32000 6400
1111 64000 12800