Datasheet

MAX11014/MAX11015
Automatic RF MESFET Amplifier
Drain-Current Controllers
8 _______________________________________________________________________________________
MISCELLANEOUS TIMING CHARACTERISTICS
PARAMETER
SYMBOL
CONDITIONS MIN TYP MAX UNITS
Minimum Time to Wait After a
Write Command Before
Reading Back Data from the
Same Location
t
RDBK
(Note 16) 1 µs
CNVST Active-Low Pulse
Width in ADC Clock Mode 01
t
CNV01
(Note 3) 20 ns
CNVST Active-Low Pulse
Width in ADC Clock Mode 11
to Initiate a Temperature
Conversion
t
CNV11
(Note 3) 20 ns
CNVST Active-Low Pulse
Width in ADC Clock Mode 11
for ADCIN1/2 Acquisition
t
ACQ11A
(Note 3) 1.5 µs
ADC Power-Up Time (External
Reference)
t
APUEXT
0.8 µs
ADC Power-Up Time (Internal
Reference)
t
APUINT
50 µs
DAC Power-Up Time (External
Reference)
t
DPUEXT
s
DAC Power-Up Time (Internal
Reference)
t
DPUINT
50 µs
Acquisition Time (Internally
Timed in ADC Clock Modes
00 or 01)
t
ACQ
0.6 µs
Conversion Time (Internally
Clocked)
t
CONV
6.5 µs
Delay to Start of Conversion
Time
t
CONVW
(Note 17) 1 µs
Temperature Conversion Time
(Internally Clocked)
t
CONVT
30 µs