Datasheet
MAX11014/MAX11015
Automatic RF MESFET Amplifier
Drain-Current Controllers
_______________________________________________________________________________________ 7
I
2
C-WIRE-INTERFACE HIGH-SPEED-MODE TIMING CHARACTERISTICS
(Note 9) (See Figure 3.)
C
B
= 100pF max C
B
= 400pF
PARAMETER
SYMBOL
CONDITIONS
MIN MAX MIN MAX
UNITS
Serial Clock Frequency f
SCL
0 3.4 0 1.7
MHz
Setup Time (Repeated) START
Condition
t
SU
;
STA
160 160 ns
Hold Time (Repeated) START
Condition
t
HD
;
STA
160 160 ns
SCL Pulse-Width Low t
LOW
160 320 ns
SCL Pulse-Width High t
HIGH
60 120 ns
Data Setup Time
t
SU
;
DAT
10 10 ns
Data Hold Time
t
HD
;
DAT
(Note 11) 0 70 0 150 ns
SCL Rise Time t
RCL
(Note 3) 10 40 20 80 ns
SCL Rise Time, After a Repeated
START Condition and After an
Acknowledge Bit
t
RCL1
(Note 3) 10 80 20 160 ns
SCL Fall Time t
FCL
(Note 3) 10 40 20 80 ns
SDA Rise Time t
RDA
(Note 3) 10 80 20 160 ns
SDA Fall Time t
FDA
(Note 3) 10 80 20 160 ns
Setup Time for STOP Condition
t
SU
;
STO
160 160 ns
Capacitive Load for Each Bus Line
C
B
(Note 14) 100 400 pF
Pulse Width of Spikes Suppressed
By the Input Filter
t
SP
(Note 15) 0 10 0 10 ns