Table 27. ALMFLAG (Read)
BIT NAME DATA BIT
RESET STATE
FUNCTION
X D15–D12 X Don’t care.
HIGH-V2 D11 0
HIGH-V2 is set to 1 when the GATE2 voltage exceeds the high threshold
setting. HIGH-V2 is reset to 0 by either a read of the ALARM flag register
or a software clear command.
LOW-V2 D10 0
LOW-V2 is set to 1 when the GATE2 voltage decreases below the low
threshold setting. LOW-V2 is reset to 0 by either a read of the ALARM
flag register or a software clear command.
HIGH-I2 D9 0
HIGH-I2 is set to 1 when the channel 2 sense voltage exceeds the high
threshold setting. HIGH-I2 is reset to 0 by either a read of the ALARM
flag register or a software clear command.
LOW-I2 D8 0
LOW-I2 is set to 1 when the channel 2 sense voltage decreases below
the low threshold setting. LOW-I2 is reset to 0 by either a read of the
ALARM flag register or a software clear command.
HIGH-T2 D7 0
HIGH-T2 is set to 1 when the channel 2 external temperature exceeds
the high threshold setting. HIGH-T2 is reset to 0 by either a read of the
ALARM flag register or a software clear command.
LOW-T2 D6 0
LOW-T2 is set to a 1 when the channel 2 external temperature
decreases below the low threshold setting. LOW-T2 is reset to 0 by
either a read of the ALARM flag register or a software clear command.
HIGH-V1 D5 0
HIGH-V1 is set to 1 when the GATE1 voltage exceeds the high threshold
setting. HIGH-V1 is reset to 0 by either a read of the ALARM flag register
or a software clear command.
LOW-V1 D4 0
LOW-V1 is set to 1 when the GATE1 voltage decreases below the low
threshold setting. LOW-V1 is reset to 0 by either a read of the ALARM
flag register or a software clear command.
HIGH-I1 D3 0
HIGH-I1 is set to 1 when the channel 1 sense voltage exceeds the high
threshold setting. HIGH-I1 is reset to 0 by either a read of the ALARM
flag register or a software clear command.
LOW-I1 D2 0
LOW-I1 is set to 1 when the channel 1 sense voltage decreases below
the low threshold setting. LOW-I1 is reset to 0 by either a read of the
ALARM flag register or a software clear command.
HIGH-T1 D1 0
HIGH-T1 is set to 1 when the channel 1 external temperature exceeds
the high threshold setting. HIGH-T1 is reset to 0 by either a read of the
ALARM flag register or a software clear command.
LOW-T1 D0 0
LOW-T1 is set to a 1 when the channel 1 external temperature
decreases below the low threshold setting. LOW-T1 is reset to 0 by
either a read of the ALARM flag register or a software clear command.