Internal Clock Mode
Select internal clock mode to release the µP from the
burden of running the SAR conversion clock. To select
this mode, bit D7 of the control byte must be set to 1 and
bit D6 must be set to zero. The internal clock frequency
is then selected, resulting in a 3.6µs conversion time.
When using the internal clock mode, connect the CLK
pin either high or low to prevent the pin from floating.
External Clock Mode
To select the external clock mode, bits D6 and D7 of
the control byte must be set to 1. Figure 6 shows the
clock and WR timing relationship for internal (Figure 6a)
and external (Figure 6b) acquisition modes with an
external clock. Proper operation requires a 100kHz to
7.6MHz clock frequency with 30% to 70% duty cycle.
Operating the MAX1060/MAX1064 with clock frequen-
cies lower than 100kHz is not recommended, because
it causes a voltage droop across the hold capacitor in
the T/H stage that results in degraded performance.
MAX1060/MAX1064
400ksps, +5V, 8-/4-Channel, 10-Bit ADCs
with +2.5V Reference and Parallel Interface
______________________________________________________________________________________ 13
WR
CLK
CLK
WR
WR GOES HIGH WHEN CLK IS HIGH.
WR GOES HIGH WHEN CLK IS LOW.
t
CWS
t
CH
t
CL
t
CP
t
CWH
ACQUISITION STARTS
ACQUISITION STARTS
CONVERSION STARTS
CONVERSION STARTS
ACQUISITION ENDS
ACQUISITION ENDS
ACQMOD = 0
ACQMOD = 0
Figure 6a. External Clock and
WR
Timing (Internal Acquisition Mode)
WR
CLK
CLK
WR
WR GOES HIGH WHEN CLK IS HIGH.
WR GOES HIGH WHEN CLK IS LOW.
t
DH
t
DH
t
CWH
t
CWS
ACQUISITION STARTS
ACQUISITION STARTS
CONVERSION STARTS
CONVERSION STARTS
ACQUISITION ENDS
ACQUISITION ENDS
ACQMOD = 1
ACQMOD = 1
ACQMOD = "0"
ACQMOD = "0"
Figure 6b. External Clock and
WR
Timing (External Acquisition Mode)