Datasheet
(I
R
= 100µA, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at T
A
= +25°C.) (Note 1)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Reverse Breakdown Voltage V
R
T
A
= +25°C
LM4050A (0.1%) 4.0919 4.0960 4.1001
VLM4050B (0.2%) 4.0878 4.0960 4.1042
LM4050C (0.5%) 4.0755 4.0960 4.1165
Reverse Breakdown Voltage
Tolerance (Note 2)
V
RTOL
LM4050A ±4.1 ±25
mVLM4050B ±8.2 ±29
LM4050C ±20 ±41
Minimum Operating Current I
RMIN
50 73 µA
Average Reverse Voltage
Temperature Coefcient
(Notes 2, 3)
DV
R
/DT
I
R
= 10mA ±30
ppm/°CI
R
= 1mA ±20 ±50
I
R
= 100µA ±15
Reverse Breakdown Voltage
Change with Operating
Current Change
I
RMIN
≤ I
R
≤ 1mA 0.5 1.2
mV
1mA ≤ I
R
≤ 15mA 3.0 10.0
Reverse Dynamic
Impedance (Note 3)
Z
R
I
R
= 1mA, f = 120Hz, I
AC
= 0.1I
R
0.5 1.0 Ω
Wideband Noise e
N
I
R
= 100µA, 10Hz ≤ f ≤ 10kHz 64 µV
RMS
Reverse Breakdown Voltage
Long-Term Stability
DV
R
T = 1000h 120 ppm
LM4050/LM4051 50ppm/°C Precision Micropower Shunt Voltage
References with Multiple Reverse Breakdown Voltages
www.maximintegrated.com
Maxim Integrated
│
6
Electrical Characteristics—4.096V