Users Guide: DS80C390 Supplement Manual
High-Speed Microcontroller User’s Guide: DS80C390 Supplement 
149 of 158 
7.  Software reads message center 2 and then programs message center 2 DTUP = 0. 
8.  The fourth message received that matches AV will be stored into message center 2, DTUP = 1, etc. 
Note that in this example message center 1 or 2 will never be overwritten. The user must insure that the 
proper number of message centers be allocated to the same arbitration value when using this arrangement. 
If software fails to read the allocated message group, an incoming message may be lost without software 
realizing it (ROW is never set when WTOE = 0). To put a message center back into operation software 
must force DTUP = 0 and EXTRQ = 0. This indicates that software has read the message center. 
Special Considerations for Message Center 15 
Message center 15 incorporates a shadow message center used to buffer incoming messages, in addition 
to the standard message center registers. When the message center is empty (DTUP=EXTRQ=0), 
incoming messages are loaded directly into the message center registers. When the message center has 
unread data (DTUP =1) or a pending remote frame request (EXTRQ = 1), incoming messages are loaded 
into the shadow message center. Unread contents of the shadow message center are automatically loaded 
into the message center when it becomes empty (DTUP=0). An overwrite condition is possible when both 
the message center 15 and shadow message centers are full. 
The response of message center 15 to the overwrite condition is dependent on the Writeover Enable 
(WTOE) bit. When overwrite is enabled (WTOE = 1) and there is unread data (DTUP =1) or a pending 
remote frame request (EXTRQ = 1), successfully received messages are stored in the shadow message 
center, overwriting existing data. If the shadow message center contained previously unread data at the 
time of the overwrite, the message center 15 ROW bit will be set. If the shadow message center was 
empty at the time of the overwrite, then the incoming message will overwrite the previous message in the 
shadow buffer and ROW will not be set to a 1. Note that the message center 15 ROW bit reflects only an 
overwrite of the shadow message center, not the message center registers as with message centers 1-14. 
When WTOE = 0 and there is unread data (DTUP =1) or a pending remote frame request (EXTRQ = 1) 
in message center 15 and there is already a message stored in the shadow buffer, incoming messages will 
not be stored in either the message center or shadow buffers. 
USING THE AUTOBAUD FEATURE 
It is sometimes necessary to connect a CAN node to a network with an unknown baud rate. The autobaud 
feature of the DS80C390 provides a simple way for the CAN module to determine the baud rate of the 
network and reconfigure the DS80C390 to operate at that baud rate. Special hardware inside the CAN 
module allows it to interface to a fully functional CAN bus and perform the autobaud feature without 
disturbing other CAN nodes. 
The theory behind the CAN autobaud feature is relatively simple. If a CAN module operating at a 
particular baud rate listens in on a CAN bus operating at a different baud rate, it will see a random bit 
stream. Because the bit stream does not conform to the CAN 2.0B protocol, a large number of bus errors 
(bit 0 error, bit 1 error, bit stuff error, etc.) will be seen by the "listening" CAN. These errors will 
increment the appropriate CAN error counter registers. With only a moderate amount of CAN traffic, 
enough errors will quickly accumulate to set the CAN Error Count Exceeded (CECE) bit in the 
DS80C390 CAN module. This can be used as an indicator that the DS80C390 is not operating at the same 
baud rate as the CAN. The DS80C390 would then adjust its baud rate and repeat the process. 










