ADDENDUM TO SECTION 16: INSTRUCTION SET DETAILS 
The DS80C390 supports one of three different address modes, selected by the AM1 and AM0 bits in the 
ACON register. The processor operates in either the traditional 16-bit address mode, 22-bit paged address 
mode or in a 22-bit contiguous address mode. When operating in the 16-bit addressing mode (AM1, AM0 
= 00b), all instruction cycle timing and byte counts will be identical to the 8051 family. Use of the 24-bit 
paged address mode is binary code-compliant with the traditional (16-bit) 8051 compilers, but allows for 
up to 4M bytes of program and 4M bytes of data memory to be supported by a new Address Page SFR 
which supports an internal bank switch mechanism. The 22-bit contiguous mode requires a compiler that 
supports contiguous program flow over the entire 22-bit address range by the addition of an operand 
and/or cycles to eight basic instructions. 
16-BIT (8051 STANDARD) ADDRESSING MODE 
This addressing mode is identical to that used by the 8051 family and most members of the high-speed 
microcontroller family. The microcontroller defaults to this mode following a reset. This mode can also 
be used to run code compiled or assembled for the 22-bit contiguous mode, as long as the following 
instructions are not executed
: 
MOV DPTR, #data24, 
ACALL addr19 
AJMP addr19 
LCALL addr24 
LJMP addr24 
These four branch instructions are the only instructions that will cause the compiler to generate additional 
operands relative to the 16-bit addressing mode. Note that the number of cycles per instruction may 
appear different from other instructions, but this is ignored by most assemblers or compilers and as such 
does not pose a problem with the binary output. 
By selecting the 24-bit contiguous mode prior using any one of these four branch instructions, it is 
possible to run 24-bit contiguous compiled code in the default 16-bit address configuration. Once the 
AM0 and AM1 bits are set to the 24-bit contiguous address mode, the instructions seen above will 
execute properly. When the 24-bit paged address mode is selected, all instructions complied under the 
traditional 16-bit address mode will execute normally at any point in code. 
22-BIT PAGED ADDRESSING MODE 
The DS80C390 incorporates an internal 8-bit Address Page Register (AP),an 8-bit extended DPTR 
Register (DPX), an 8-bit extended DPTR1 Register (DPX1), and an 8-bit MOVX Extended Address 
Register as hardware support for 22-bit addressing in the paged address mode (AM1, AM0 = 01b). This 
mode has two differences in code execution from the traditional 16-bit mode: 
1.  The first difference is the additional of one machine cycle when executing the ACALL, LCALL, RET 
and RETI instructions as well as when the hardware processes an interrupt. This change should be 
transparent to most compilers, as the byte count remains identical for these instructions. 
2.  The second instruction involves register indirect MOVX instructions such as 
MOVX @Ri, A or 
MOVX A, @Ri. When in this mode, the MXAX register supplies the upper 8-bits of the 22-bit (or 
23-bit if CMA=1 or IDM1=) address bits of the MOVX address. The complete address is formed by 
concatenating MXAX, P2, and R1 or R0 in this mode. The DPTR-related MOVX instructions do not 
utilize the P2 and MXAX register. 