11.6 Timer 2
Like Timers 0 and 1, Timer 2 is a full-function timer/counter, however it has several additional
capabilities that make it more useful. Timer 2 has independent control registers in T2CON
and T2MOD,
and is based on count registers TL2
and TH2. All these registers are described in detail below.
11.6.1 Timer Two Control Register (T2CON) Summary
7 6 5 4 3 2 1 0
T2CON
C8h
TF2 EXF2
RCLK
TCLK EXEN2 TR2
C/
T2 CP/RL2
Bit 7: Timer 2 Overflow Flag (TF2). Hardware will set TF2 when the Timer 2 overflows from FFFFh to
0000h, or from the count equal to the capture register in down count mode. It must be cleared to 0 by
software. TF2 will only be set to a 1 if RCLK and TCLK are both cleared to a 0.
Bit 6: Timer 2 External Flag (EXF2). Hardware will set EXF2 when a reload or capture is caused by a
falling transition on the T2EX pin (P1.1). EXEN2 must be set for this function. This flag must be cleared
to 0 by software. Writing a one to this bit will force a timer interrupt if enabled.
Bit 5: Receive Clock Flag (RCLK). This bit determines whether Timer 1 or 2 is used for Serial Port 0
timing of received data in Serial Modes 1 or 3. RCLK = 1 causes Timer 2 overflow to be used as the
receive clock. RCLK = 0 causes Timer 1 overflow to be used as the receive clock.
Bit 4: Transmit Clock Flag (TCLK). This bit determines whether Timer 1 or 2 is used for Serial Port 0
timing of Transmit data in Serial Modes 1 or 3. TCLK = 1 causes Timer 2 overflow to be used as the
transmit clock. TCLK = 0 causes Timer 1 overflow to be used as the transmit clock.
Bit 3: Timer 2 External Enable (EXEN2). Setting this bit to a 1 allows a capture or reload to occur as a
result of a falling transition on T2EX (P1.1), if Timer 2 is not generating baud rates for the serial port.
EXEN2 = 0 causes Timer 2 to ignore all external events at T2EX.
Bit 2: Timer 2 Run (TR2). Setting this bit to a 1 starts Timer 2. Setting it to a 0 stops Timer 2.
Bit 1: Counter/Timer Select (C/T2). Setting this bit to a 0 selects a timer function for Timer 2. Setting it
to a 1 selects a counter of falling transitions on T2 (P1.0). Timer 2 runs at 4 clocks per tick or 12 clocks
per tick as programmed by CKCON
.5. This bit will be overridden and Timer 2 directed to use a divide-
by-2 clock if either the baud-rate generator or clock output mode is used.
Bit 0: Capture/Reload Flag (CP/RL2). When this bit is set to 1, Timer 2 captures will occur on 1-to-0
transitions of T2EX (P1.1) if EXEN2 = 1. When this bit is set to 0, auto-reloads will occur when Timer 2
overflows or when 1-to-0 transitions occur on T2EX if EXEN2 = 1. If either RCLK or TCLK is set to a 1
this bit will not function and the timer will function in an auto-reload mode following each overflow.