Datasheet
DS75 
 5 of 14 
AC ELECTRICAL CHARACTERISTICS  (-55°C to +125°C; 2.7V ≤ V
DD
 ≤ 5.5V) 
PARAMETER SYMBOL CONDITION MIN TYP MAX UNITS NOTES 
Resolution 
9 12 bits  
9-bit 
conversions 
 150 
10-bit 
conversions 
 300 
11-bit 
conversions 
 600 
Temperature 
Conversion Time 
t
CONVT
12-bit 
conversions 
 1200 
ms 
SCL Frequency  f
SCL
 400 KHz  
Bus Free Time 
Between a STOP and 
START Condition 
t
BUF
1.3 
μs 
5 
START and Repeated 
START Hold Time 
from Falling SCL 
t
HD:STA 
0.6 
μs 
5, 6 
Low Period of SCL  t
LOW
1.3  
μs 
5 
High Period of SCL  t
HIGH
0.6  
μs 
5 
Repeated START 
Condition Setup Time 
to Rising SCL 
t
SU:STA 
0.6 
μs 
5 
Data-Out Hold Time 
from Falling SCL 
t
HD:DAT 
0 
 0.9 
μs 
5 
Data-In Setup Time to 
Rising SCL 
t
SU:DAT 
 100 
 ns 5 
Rise Time of SDA and 
SCL 
t
R
    20 + 0.1C
B
1000 
ns 5, 7 
Fall Time of SDA and 
SCL 
t
F
 20 +
0.1C
B
  300  ns  5, 7 
STOP Setup Time to 
Rising SCL 
t
SU:STO 
 0.6 
μs 
5 
Capacitive Load for 
Each Bus Line 
C
B
    400 pF  
Input Capacitance  C
I
   5  pF  
NOTES: 
1. All voltages are referenced to ground. 
2. Internal heating caused by O.S. loading will cause the DS75 to read approximately 0.5°C higher if 
O.S. is sinking the max rated current. 
3. I
DD
 specified with O.S. pin open. 
4. I
DD
 specified with V
DD
 at 5.0V and SDA, SCL = 5.0V, 0°C to 70°C. 
5. See Timing Diagram in Figure 2. All timing is referenced to 0.9 x V
DD
 and 0.1 x V
DD
. 
6. After this period, the first clock pulse is generated. 
7. For example, if C
B 
= 300pF, then t
R
[min] = t
F