Datasheet
DS75LX: Digital Thermometer and Thermostat with Extended Addressing 
  3 of 13  
SCL Frequency  f
SCL
  400 kHz 
AC ELECTRICAL CHARACTERISTICS (continued) 
(1.7V ≤ V
DD
 ≤ 3.7V, T
A
 = -55°C to +125°C.) 
PARAMETER SYMBOL  CONDITIONS  MIN TYP MAX UNITS 
Bus Free Time Between 
a STOP and START 
Condition 
t
BUF
(Note 7) 
1.3 
 µs 
START and Repeated 
START Hold Time from 
Falling SCL 
t
HD:STA
(Notes 7, 8) 
600 
 ns 
Low Period of SCL  t
LOW
(Note 7)  1.3      µs 
High Period of SCL  t
HIGH
(Note 7)  0.6      µs 
Repeated START 
Condition Setup Time to 
Rising SCL 
t
SU:STA
(Note 7)  600      ns 
Data-Out Hold Time from 
Falling SCL 
t
HD:DAT
(Notes 7, 9)  0    0.9  µs 
Data-In Setup Time to 
Rising SCL 
t
SU:DAT
(Note 7) 
100 
 ns 
Rise Time of SDA and 
SCL (Receive) 
t
R
(Notes 7, 10) 
20 + 
0.1C
B
B
 300 ns 
Fall Time of SDA and 
SCL (Receive) 
t
F
(Notes 7, 10) 
20 +
0.1C
B
B
 300 ns 
Spike Suppression 
Filter Time (Deglitch 
Filter) 
t
SS
 0  50 ns 
STOP Setup Time to 
Rising SCL 
t
SU:STO
(Note 7)  600      ns 
Capacitive Load for Each 
Bus Line 
C
B
B   400 pF 
Input Capacitance  C
I
 5  pF 
Serial Interface Reset 
Time 
t
TIMEOUT
SDA time low 
(Notes 11, 12) 
75 325 ms 
Note 1:  V
DD
 must be decoupled with a high-quality 0.1µF bypass capacitor. X5R or X7R ceramic surface-mount capacitors are 
recommended. 
Note 2: 
Internal heating caused by O.S. loading causes the DS75LX to read approximately 0.5°C higher if O.S. is sinking the max 
rated current. 
Note 3:  All voltages are referenced to ground. 
Note 4:  I
DD
 specified with O.S. pin open and A0–A2 pins grounded. 
Note 5: 
I
DD
 and address leakage specified with V
DD
 at 3.0V and SDA, SCL = 3.0V at 0°C to +70°C. 
Note 6:  Address pins A0, A1, A2 are directly connected to V
DD
, V
SS
, or floating with less than 50pF capacitive load. 
Note 7:  See the timing diagram (Figure 1). All timing is referenced to 0.9 x V
DD
 and 0.1 x V
DD
. 
Note 8:  After this period, the first clock pulse is generated. 
Note 9:  The DS75LX provides an internal hold time of at least 75ns on the SDA signal to bridge the undefined region of SCL's falling 
edge. 
Note 10:  For example, if C
B 
= 300pF, then t
R
[min] = t
F
[min] = 50ns. 
Note 11:  This timeout applies only when the DS75LX is holding SDA low. Other devices can hold SDA low indefinitely and the DS75LX 
will not reset. 
Note 12:  The DS75LX is available with timeout feature disabled upon special order. Contact Factory. 
PIN DESCRIPTION 
PIN  NAME  FUNCTION 
1  SDA  Data Input/Output for 2-Wire Serial Communication Port (Open Drain) 
2  SCL  Clock Input for 2-Wire Serial Communication Port 
3  O.S.  Thermostat Output Open Drain 
4 GND Ground  
5 A
2
Address Input 
6 A
1
Address Input 
7 A
0
Address Input 
8 V
DD
Supply Voltage. +1.7V to +3.7V supply pin. V
DD
 must have an external bypass 
capacitor to GND. 0.1µF X5R or X7R ceramic SMT caps recommended. 