Conguration Register
The configuration register allows the user to program
various DS75LV options such as conversion resolution,
thermostat fault tolerance, thermostat polarity, thermostat
operating mode, and shutdown mode. The configuration
register is arranged as shown in Figure 5 and detailed
descriptions of each bit are provided in Table 2. The user
has read/write access to all bits in the configuration reg-
ister except the MSb, which is a reserved read-only bit.
The entire register is volatile, and thus powers up in its
default state.
Figure 4. OS Output Operation Example
Figure 5. Configuration Register
IN THIS EXAMPLE THE DS75LV
IS CONFIGURED TO HAVE A FAULT
TOLERANCE OF 2.
OS OUTPUT - COMPARATOR MODE
CONVERSIONS
INACTIVE
ACTIVE
TEMPERATURE
T
OS
T
HYST
INACTIVE
ACTIVE
OS OUTPUT - INTERRUPT MODE
ASSUMES A READ
HAS OCCURRED
MSb BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 LSb
0 R1 R0 F1 F0 POL TM SD
DS75LV Digital Thermometer and Thermostat
www.maximintegrated.com
Maxim Integrated
│
7