Datasheet

DS620 Digital Thermometer and Thermostat
3 of 15
ABSOLUTE MAXIMUM RATINGS
Voltage Range on Any Pin, Relative to Ground -0.5V to +4.5V
Operating Temperature Range -55°C to +125°C
Storage Temperature Range
-55°C to +125°C
Soldering Temperature
See IPC/JEDEC J-STD-020A Specification
ESD rating on all pins 4KV HBM
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only,
and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is
not implied. Exposure to the absolute maximum rating conditions for extended periods may affect device.
RECOMMENDED DC OPERATING CONDITIONS
(3.5V V
DD
1.7V, T
A
= -55°C to +125°C.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Voltage Range on Any Pin,
Relative to Ground
V
DD
(Note 1) 1.7 3.5 V
Supply Voltage for EEPROM
Writes
V
DD
(Note 1) 2.0 3.5 V
DC ELECTRICAL CHARACTERISTICS
(3.5V V
DD
1.7V, T
A
= -55°C to +125°C.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
0°C to +70°C ±0.5
Thermometer Error T
ERR
-55°C to +125°C ±2
°C
Input Logic High V
IH
(Note 1)
0.7 x
V
DD
V
DD
+
0.5
V
Input Logic Low V
IL
(Note 1) - 0.5
0.3 x
V
DD
V
V
OL1
3mA sink current (Note 1) 0 0.4
SDA Output Logic Low Voltage
V
OL2
6mA sink current (Note 1) 0 0.6
V
PO Saturation Voltage V
OL
4mA sink current (Note 1) 0 0.4 V
Input Current for each I/O pin 0.4 < V
I/O
< 0.9 x V
DD
-10 +10 µA
I/O Capacitance C
I/O
10 pF
Standby Current I
STBY
0°C to +70°C (Note 2) 2 µA
Temperature conversion, -
55°C to +85°C (Note 3)
800
Temperature conversion,
+85°C to +125°C (Note 3)
900
µA
Active Supply Current I
DD
E
2
write (Note 3) 500 µA
10 bit 25
11 bit 50
12 bit 100
Temperature Conversion Time T
TC
13 bit 200
ms
Note 1: All voltages are referenced to GND.
Note 2: Specified with SDA = V
DD
; A
0
, A
1
, A
2
= 0V or V
DD
.
Note 3: Specified with A
0
, A
1
, A
2
= 0V or V
DD
.