DPWM Soft-Start
At the beginning of each lamp burst, the DS3881 pro-
vides a soft-start that slowly increases the MOSFET
gate-driver duty cycle (see Figure 6). This minimizes
the possibility of audible transformer noise that could
result from current surges in the transformer primary.
The soft-start length is fixed at 16 lamp cycles, but the
soft-start ramp profile is programmable through the
four soft-start profile registers (SSP1/2/3/4) and can
be adjusted to match the application. There are seven
different driver duty cycles to select from to customize
the soft-start ramp (see Tables 4a and 4b). The avail-
able duty cycles range from 0% to 19% in ~3% incre-
ments. In addition, the MOSFET duty cycle from the
last lamp cycle of the previous burst can be used as
part of the soft-start ramp by using the most recent
value duty cycle code. Each programmed MOSFET
gate duty cycle repeats twice to make up the 16 soft-
start lamp cycles.