Datasheet

____________________________________________________ DS34T101, DS34T102, DS34T104, DS34T108
227 of 366
Addr
Offset
Register Name Description
Read/Write or
Read Only
Page
2C0 RRTS1 Rx Real-Time Status Register 1 R 267
2C8
RRTS3-T1
RRTS3-E1
Rx R
eal-Time Status Register 3 (T1 Mode)
Rx Real-Time Status Register 3 (E1 Mode)
R
268
268
2D0 RRTS5 Rx Real-Time Status Register 5 R 269
2D4 RHPBA Rx HDLC Packet Bytes Available Register R 269
2D8 RHF Rx HDLC FIFO Register R 270
300 RBCS1 Rx Blank Channel Select Register 1 R/W 270
304 RBCS2 Rx Blank Channel Select Register 2 R/W 270
308 RBCS3 Rx Blank Channel Select Register 3 R/W 270
30C RBCS4 Rx Blank Channel Select Register 4 (E1 Mode Only) R/W 270
320 RSI1 Rx Signaling Reinsertion Enable Reg 1 R/W 270
324 RSI2 Rx Signaling Reinsertion Enable Reg 2 R/W 270
328 RSI3 Rx Signaling Reinsertion Enable Reg 3 R/W 270
32C RSI4 Rx Signaling Reinsertion Enable Reg 4 (E1 Only) R/W 270
340 RCICE1 Rx Channel Idle Code Enable Reg 1 R/W 271
344 RCICE2 Rx Channel Idle Code Enable Reg 2 R/W 271
348 RCICE3 Rx Channel Idle Code Enable Reg 3 R/W 271
34C RCICE4 Rx Channel Idle Code Enable Reg 4 (E1 Only) R/W 271
350 RBPCS1 Rx BERT Port Channel Select Register 1 R/W 271
354 RBPCS2 Rx BERT Port Channel Select Register 2 R/W 271
358 RBPCS3 Rx BERT Port Channel Select Register 3 R/W 271
35C RBPCS4 Rx BERT Port Channel Select Register 4 (E1 Only) R/W 271
Register Name:
RDMWE1-E1, RDMWE2-E1, RDMWE3-E1, RDMWE4-E1
Register Description:
Receive Digital Milliwatt Enable Registers (E1 Mode Only)
Register Address:
base address + 0x000, 0x004, 0x008, 0x00C
Bit # 7 6 5 4 3 2 1 0
RDMWE1-E1 CH8 CH7 CH6 CH5 CH4 CH3 CH2 CH1
RDMWE2-E1 CH16 CH15 CH14 CH13 CH12 CH11 CH10 CH9
RDMWE3-E1 CH24 CH23 CH22 CH21 CH20 CH19 CH18 CH17
RDMWE4-E1 CH32 CH31 CH30 CH29 CH28 CH27 CH26 CH25
Note: These registers are only used in E1 mode. The RDMWE1-T1 RDMWE3-T1 registers are used in T1 mode.
Bits 7 to 0 (x4): E1 Rx Digital Milliwatt Enable for Channels 1 to 32 (CH1 to CH32). Register bit RCR3.uALAW
spe
cifies whether u-law or A-law coding is used for the digital milliwatt code. See section 10.11.13.
0 = Do n
ot affect the Rx data associated with this channel
1 = Replace the Rx data associated with this channel with digital milliwatt code
Register Name:
RHC
Register Description:
Receive HDLC Control Register
Register Address:
base address + 0x040
Bit # 7 6 5 4 3 2 1 0
Name RCRCD RHR RHMS RHCS4 RHCS3 RHCS2 RHCS1 RHCS0
Default 0 0 0 0 0 0 0 0
Bit 7: Receive CRC-16 Display (RCRCD). See section 10.12.1.
0 = Do not write received CRC-16
code to FIFO. (default)
1 = Write received CRC-16 code to FIFO after last octet of packet.