Datasheet
DS26521 Single T1/E1/J1 Transceiver
219 of 258
Register Name:
BSIM
Register Description:
BERT Status Interrupt Mask Register
Register Address:
110Fh
Bit # 7 6 5 4 3 2 1 0
Name — BBED BBCO BECO BRA1 BRA0 BRLOS BSYNC
Default 0 0 0 0 0 0 0 0
Bit 6: BERT Bit-Error-Detected Event (BBED).
0 = interrupt masked
1 = interrupt enabled
Bit 5: BERT Bit Counter Overflow Event (BBCO).
0 = interrupt masked
1 = interrupt enabled
Bit 4: BERT Error Counter Overflow Event (BECO).
0 = interrupt masked
1 = interrupt enabled
Bit 3: BERT Receive All-Ones Condition (BRA1).
0 = interrupt masked
1 = interrupt enabled—interrupts on rising and falling edges
Bit 2: BERT Receive All-Zeros Condition (BRA0).
0 = interrupt masked
1 = interrupt enabled—interrupts on rising and falling edges
Bit 1: BERT Receive Loss of Synchronization Condition (BRLOS)
0 = interrupt masked
1 = interrupt enabled—interrupts on rising and falling edges
Bit 0: BERT in Synchronization Condition (BSYNC).
0 = interrupt masked
1 = interrupt enabled—interrupts on rising and falling edges