Datasheet
DS26521 Single T1/E1/J1 Transceiver
139 of 258
Register Name:
T1RSCC (T1 Mode Only)
Register Description:
In-Band Receive Spare Control Register
Register Address:
089h
Bit # 7 6 5 4 3 2 1 0
Name — — — — — RSC2 RSC1 RSC0
Default 0 0 0 0 0 0 0 0
Bits 2 to 0: Receive Spare Code Length Definition Bits (RSC[2:0]).
RSC2 RSC1 RSC0
LENGTH SELECTED
(BITS)
0 0 0 1
0 0 1 2
0 1 0 3
0 1 1 4
1 0 0 5
1 0 1 6
1 1 0 7
1 1 1 8:16
Register Name:
RXPC
Register Description:
Receive Expansion Port Control Register
Register Address:
08Ah
Bit # 7 6 5 4 3 2 1 0
Name
— — — —
— RBPDIR RBPFUS RBPEN
— — — —
—
RBPDIR
—
RBPEN
Default 0 0 0 0 0 0 0 0
Bit 2: Receive BERT Port Direction Control (RBPDIR).
0 = Normal (line) operation. Receive BERT port receives data from the receive framer.
1 = System (backplane) operation. Receive BERT port receives data from the transmit path. The transmit
path enters the receive BERT on the line side of the elastic store (if enabled).
Bit 1: Receive BERT Port Framed/Unframed Select (RBPFUS) (T1 Mode Only).
0 = The receive BERT will not clock data from the F-bit position (framed).
1 = The receive BERT will clock data from the F-bit position (unframed).
Bit 0: Receive BERT Port Enable (RBPEN).
0 = Receive BERT port is not active.
1 = Receive BERT port is active.