Figure 6-12. PRBS Synchronization State Diagram
Sync
LoadVerify
1 bit error
32 bits loaded
3
2
b
i
ts
w
i
th
o
u
t
e
r
ro
r
s
6
o
f
6
4
b
it
s
w
it
h
e
rr
o
rs
6.9.3.2 Receive Repetitive Pattern Synchronization
Repetitive pattern synchronization synchronizes the receive pattern generator to the incoming repetitive pattern.
The receive pattern generator is synchronized by searching each incoming data stream bit position for the
repetitive pattern, and then checking the next 32 data stream bits. Synchronization is achieved if all 32 bits match
the incoming pattern. If at least six incoming bits in the current 64-bit window do not match the receive PRBS
pattern generator, automatic pattern resynchronization is initiated. Automatic pattern resynchronization can be
disabled.