Maxim Integrated ........................................................................................................................................................................................... 31
AC ELECTRICAL CHARACTERISTICS (V
DD
= 4.5V to 5.5V; -40°C to +85°C)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
NOTES
UART Bit Time
T
T
8.68
104
μs
6
Device Bit Time
T
R
8.68
104
μs
6, 7, 16
Fall Time RXD
t
FR
8
20
ns
8,17
Rise Time RXD
t
RR
13
27
ns
8,17
Transmit Idle Time
t
IDLET
0
μs
9
Receive Idle Time
t
IDLER
t
IDLET
μs
Asymmetry
t
ASYM
1
μs
10
Arrival Response Time
t
ARR
4.4
52
μs
11
Master Reset Time
t
MR
104
μs
12
Active Pullup on Time
t
APUOT
0.5
2.0
μs
13
Response Time
t
RESP
8.68 + ∆
104 + ∆
μs
11, 14
NOTES:
1. V
PP
- ∆V
PROG
must be within 11.5V to 12.0V.
2. Applies only if a 12.0V supply is connected. If V
PP
and V
DD
are tied together, current is less than
1µA.
3. Input load is to GND.
4. Voltage difference between V
DD
and 1-W.
5. Voltage difference between V
PP
and 1-W.
6. 8.68µs (115.2kbps), 52µs (19.2kbps), 17.36µs (57.6kbps), 104µs (9.6kbps).
7. Nominal values; tolerance = ±5%.
8. At V
CC
= 5.0V and 100pF load to GND.
9. See Table 7, Function and Speed Matrix.
10. Independent of baud rate.
11. Minimum at 115.2kbps, maximum at 9.6kbps.
12. The master reset cycle is complete after t
MR
is over.
13. Minimum value at Overdrive speed; maximum value at standard speed.
14. ∆ is the time to complete the activity on the 1-Wire bus; values range from 0 (configuration
command) up to 5130µs (alarming presence pulse).
15. With standard and flexible speed the total capacitive load of the 1-Wire bus should not exceed 20nF,
otherwise the active pullup on threshold V
IAPO
may not be reached in the available time. With
Overdrive speed the capacitive load on the 1-Wire bus must not exceed 1nF.
16. Baud rate calibration is valid at a static V
DD
operating point. Post calibration changes in V
DD
by more
than 5% may cause calibration error to exceed 5%. The DS2480B requires a 1-Wire reset command
sent by the host at a data rate of 9600bps for calibration. Data rates of 115200bps or higher during
calibration may put the DS2480B in an undefined state, requiring a power-down reset to restore
normal operation.
17. Not production tested.
Package Information
For the latest package outline information and land patterns, go to www.maximintegrated.com/packages. Note that a “+”, “#”, or “-“ in the
package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing pertains to the package
regardless of RoHS status.
PACKAGE TYPE PACKAGE CODE DOCUMENT NO.
8 SO S8+5 21-0041