Datasheet

DS2155
166 of 238
Register Name:
RUPCD1
Register Description:
Receive Up-Code Definition Register 1
Register Address:
B9h
Bit # 7 6 5 4 3 2 1 0
Name C7 C6 C5 C4 C3 C2 C1 C0
Default 0 0 0 0 0 0 0 0
Note: Writing this register resets the detector’s integration period.
Bit 0/Receive Up-Code Definition Bits 0 (C0). A don’t care if a 1-bit to 7-bit length is selected.
Bit 1/Receive Up-Code Definition Bit 1 (C1). A don’t care if a 1-bit to 6-bit length is selected.
Bit 2/Receive Up-Code Definition Bit 2 (C2). A don’t care if a 1-bit to 5-bit length is selected.
Bit 3/Receive Up-Code Definition Bit 3 (C3). A don’t care if a 1-bit to 4-bit length is selected.
Bit 4/Receive Up-Code Definition Bit 4 (C4). A don’t care if a 1-bit to 3-bit length is selected.
Bit 5/Receive Up-Code Definition Bit 5 (C5). A don’t care if a 1-bit or 2-bit length is selected.
Bit 6/Receive Up-Code Definition Bit 6 (C6). A don’t care if a 1-bit length is selected.
Bit 7/Receive Up-Code Definition Bit 7 (C7). First bit of the repeating pattern.
Register Name:
RUPCD2
Register Description:
Receive Up-Code Definition Register 2
Register Address:
BAh
Bit # 7 6 5 4 3 2 1 0
Name C7 C6 C5 C4 C3 C2 C1 C0
Default 0 0 0 0 0 0 0 0
Bits 0–7/Receive Up-Code Definition Bits 0–7 (C0–C7). A don’t care if a 1-bit to 7-bit length is selected.