RUPCD: RECEIVE UP CODE DEFINITION REGISTER (Address=14 Hex)
(MSB) (LSB)
C7 C6 C5 C4 C3 C2 C1 C0
SYMBOL POSITION NAME AND DESCRIPTION
C7 RUPCD.7 Receive Up Code Definition Bit 7. First bit of the repeating pattern.
C6 RUPCD.6 Receive Up Code Definition Bit 6. A Don’t Care if a 1 bit length is selected.
C5 RUPCD.5 Receive Up Code Definition Bit 5. A Don’t Care if a 1 or 2 bit length is selected.
C4 RUPCD.4 Receive Up Code Definition Bit 4. A Don’t Care if a 1 to 3 bit length is selected.
C3 RUPCD.3 Receive Up Code Definition Bit 3. A Don’t Care if a 1 to 4 bit length is selected.
C2 RUPCD.2 Receive Up Code Definition Bit 2. A Don’t Care if a 1 to 5 bit length is selected.
C1 RUPCD.1 Receive Up Code Definition Bit 1. A Don’t Care if a 1 to 6 bit length is selected.
C0 RUPCD.0 Receive Up Code Definition Bit 0. A Don’t Care if a 1 to 7 bit length is selected.
RDNCD: RECEIVE DOWN CODE DEFINITION REGISTER (Address=15 Hex)
(MSB) (LSB)
C7 C6 C5 C4 C3 C2 C1 C0
SYMBOL POSITION NAME AND DESCRIPTION
C7 RDNCD.7 Receive Down Code Definition Bit 7. First bit of the repeating pattern.
C6 RDNCD.6 Receive Down Code Definition Bit 6. A Don’t Care if a 1 bit length is selected.
C5 RDNCD.5 Receive Down Code Definition Bit 5. A Don’t Care if a 1 or 2 bit length is selected.
C4 RDNCD.4 Receive Down Code Definition Bit 4. A Don’t Care if a 1 to 3 bit length is selected.
C3 RDNCD.3 Receive Down Code Definition Bit 3. A Don’t Care if a 1 to 4 bit length is selected.
C2 RDNCD.2 Receive Down Code Definition Bit 2. A Don’t Care if a 1 to 5 bit length is selected.
C1 RDNCD.1 Receive Down Code Definition Bit 1. A Don’t Care if a 1 to 6 bit length is selected.
C0 RDNCD.0 Receive Down Code Definition Bit 0. A Don’t Care if a 1 to 7 bit length is selected.