Datasheet
DS21348/DS21Q348
29 of 76
4. CONTROL REGISTERS
CCR1 (00H): COMMON CONTROL REGISTER 1
(MSB)
(LSB)
ETS NRZE RCLA ECUE JAMUX TTOJ TTOR LOTCMC
SYMBOL POSITION DESCRIPTION
ETS CCR1.7
E1/T1 Select.
0 = E1
1 = T1
NRZE CCR1.6
NRZ Enable.
0 = Bipolar data at RPOS/RNEG and TPOS/TNEG
1 = NRZ data at RPOS and TPOS or TNEG; RNEG outputs a positive
going pulse when device receives a BPV, CV, or EXZ. See Figure 1-2
and Figure 1-3.
RCLA CCR1.5
Receive Carrier Loss Alternate Criteria.
0 = RCL declared upon 255 (E1) or 192 (T1) consecutive zeros
1 = RCL declared upon 2048 (E1) or 1544 (T1) consecutive zeros
ECUE CCR1.4 Error Counter Update Enable. A 0 to 1 transition forces the next clock
cycle to load the error counter registers with the latest counts and reset
the counters. The user must wait a minimum of two clocks cycles (976ns
for E1 and 1296ns for T1) before reading the error count registers to
allow for a proper update. See Section 4 and Figure 1-2 for details.
JAMUX CCR1.3 Jitter Attenuator MUX. Controls the source for JACLK (Figure 1-1).
0 = JACLK sourced from MCLK (2.048MHz or 1.544MHz at MCLK)
1 = JACLK sourced from internal PLL (2.048MHz at MCLK)
TTOJ CCR1.2 TCLK to JACLK. Internally connects TCLK to JACLK (Figure 1-3).
0 = disabled
1 = enabled
TTOR CCR1.1 TCLK to RCLK. Internally connects TCLK to RCLK (Figure 1-3
).
0 = disabled
1 = enabled
LOTCMC CCR1.0 Loss Of Transmit Clock Mux Control. Determines whether the
transmit logic should switch to JACLK if the TCLK input should fail to
transition (Figure 1-3
).
0 = do not switch to JACLK if TCLK stops
1 = switch to JACLK if TCLK stops