Datasheet
DS1920 
  14 of 22 
MEMORY AND CONTROL FUNCTIONS FLOWCHART (continued) Figure 9 
1-Wire SIGNALING 
The DS1920 requires strict protocols to ensure data integrity. The protocol consists of five types of 
signaling on one line: Reset Sequence with Reset Pulse and Presence Pulse, Write 0, Write 1, Read Data 
and Strong Pullup. All these signals except Presence Pulse are initiated by the bus master. The 
initialization sequence required to begin any communication with the DS1920 is shown in Figure 10. A 
Reset Pulse followed by a Presence Pulse indicates the DS1920 is ready to accept a ROM command. The 
bus master transmits (Tx) a Reset Pulse (t
RSTL
, minimum 480µs). The bus master then releases the line 
and goes into receive mode (Rx). The 1-Wire bus is pulled to a high state via the pullup resistor. After 
detecting the rising edge on the 1-Wire line, the DS1920 waits (t
PDH
, 15–60µs) and then transmits the 
Presence Pulse (t
PDL
, 60–240µs). 










