Datasheet

DS1886
SFP and PON ONU Controller
with Digital LDD Interface
86Maxim Integrated
A2h Table 02h, Register F5h: TXSTAT1
A2h Table 02h, Register F6h: DPCSTAT
A2h Table 02h, Register F7h: RXSTAT
A2h Table 02h, Register F8h–FFh: RESERVED
FACTORY DEFAULT 00h
READ ACCESS PW2 or (PW1 and RWTBL246) or (PW1 and RBL246)
WRITE ACCESS N/A
MEMORY TYPE Nonvolatile (SEE)
F5h 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
BIT 7 BIT 0
A 3-wire slave register. This value is read from a Maxim laser driver with the 3-wire interface every t
RR
(see the
Analog Voltage Monitoring Characteristics table).
FACTORY DEFAULT 00h
READ ACCESS PW2 or (PW1 and RWTBL246) or (PW1 and RBL246)
WRITE ACCESS N/A
MEMORY TYPE Nonvolatile (SEE)
F6h 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
BIT 7 BIT 0
A 3-wire slave register. This value is read from a Maxim laser driver with the 3-wire interface every t
RR
(see the
Analog Voltage Monitoring Characteristics table).
FACTORY DEFAULT 00h
READ ACCESS PW2 or (PW1 and RWTBL246) or (PW1 and RBL246)
WRITE ACCESS N/A
MEMORY TYPE Nonvolatile (SEE)
F7h 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
BIT 7 BIT 0
A 3-wire slave register. This value is read from a Maxim laser driver with the 3-wire interface every t
RR
(see the
Analog Voltage Monitoring Characteristics table).
FACTORY DEFAULT 00h
READ ACCESS N/A
WRITE ACCESS N/A
MEMORY TYPE Nonvolatile (SEE)
These registers are reserved.