Datasheet
DS1886
SFP and PON ONU Controller
with Digital LDD Interface
71Maxim Integrated
A2h Table 02h, Register AEh–AFh: INTERNAL TEMP OFFSET
A2h Table 02h, Register B0h–B3h: PW1
FACTORY CALIBRATED
READ ACCESS PW2 or (PW1 and RWTBL246) or (PW1 and RBL246)
WRITE ACCESS PW2 or (PW1 and RWTBL246)
MEMORY TYPE Nonvolatile (SEE)
AEh S 2
8
2
7
2
6
2
5
2
4
2
3
2
2
AFh 2
1
2
0
2
-1
2
-2
2
-3
2
-4
2
-5
2
-6
BIT 7 BIT 0
Allows for offset control of temp measurement if desired. The final result must be XORed with BB40h before writing
to this register. Factory calibration contains the desired value for a reading in degrees Celsius.
FACTORY DEFAULT FFFF FFFFh
READ ACCESS N/A
WRITE ACCESS PW2 or (PW1 and WPW1)
MEMORY TYPE Nonvolatile (SEE)
B0h 2
31
2
30
2
29
2
28
2
27
2
26
2
25
2
24
B1h 2
23
2
22
2
21
2
20
2
19
2
18
2
17
2
16
B2h 2
15
2
14
2
13
2
12
2
11
2
10
2
9
2
8
B3h 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
BIT 7 BIT 0
The PWE value is compared against the value written to this location to enable PW1 access. At power-on, the
PWE value is set to all ones. Thus, writing these bytes to all ones grants PW1 access on power-on without writing
the password entry. All reads of this register are 00h.