Datasheet

DS1878
SFP+ Controller with Digital LDD Interface
______________________________________________________________________________________ 93
Table 02h, Register F7h: 3WSET
FACTORY DEFAULT 00h
READ ACCESS PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)
WRITE ACCESS PW2 or (PW1 and RWTBL246)
MEMORY TYPE Nonvolatile (SEE)
F7h RESERVED RESERVED RESERVED RESERVED RESERVED TXPORDIS EXCTRL1 EXCTRL2
BIT 7 BIT 0
BITS 7:3 RESERVED
BIT 2
TXPORDIS: Transmit POR Disable.
0 = The 3-wire interface monitors the TXPOR bit in the laser drivers TXSTAT1 register.
1 = The 3-wire interface ignores the TXPOR bit in the laser drivers TXSTAT1 register.
BITS 1:0
EXCTRL[1:0]: Extra 3-Wire Control Register Selection. Used to enable/disable the 3-wire registers.
00 = SETTXEQ and SETLOSTIMER are enabled.
01 = Device mode. SETTEXEQ, SETLOSTIMER, RXCTRL3, TXCTRL2, and TXCTRL3 are disabled.
10 = SETTXEQ, SETLOSTIMER, and RXCTRL3 are enabled.
11 = SETTXEQ, SETLOSTIMER, RXCTRL3, TXCTRL2, and TXCTRL3 are enabled.
Table 02h, Register F8h: 3WCTRL
FACTORY DEFAULT 00h
READ ACCESS PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)
WRITE ACCESS PW2 or (PW1 and RWTBL246)
MEMORY TYPE Volatile
F8h RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED 3WRW 3WDIS
BIT 7 BIT 0
BITS 7:2 RESERVED
BIT 1
3WRW: Initiates a 3-wire write or read operation. The write command uses the memory address
found in the 3-wire ADDRESS register (Table 02h, Register F9h) and the data from the 3-wire WRITE
register (Table 02h, Register FAh). This bit clears itself at the completion of the write operation.
The read command uses the memory address found in the 3-wire ADDRESS register (Table 02h,
Register F9h). The address determines whether a read or write operation is to be performed. This
bit clears itself at the completion of the read operation.
0 = (Default) Reads back as 0 when the write or read operation is completed.
1 = Initiates a 3-wire write or read operation.
BIT 0
3WDIS: Disables all automatic communication across the 3-wire interface. This includes all
updates from the LUTs, APC loop, and status registers. The only 3-wire communication is with the
manual mode of operation.
0 = (Default) Automatic communication is enabled.
1 = Disables automatic communication.