Datasheet

55Maxim Integrated
SFP Controller for Dual Rx Interface
DS1877
Table 02h, Register BCh: LOS RANGING
1
FACTORY DEFAULT 00h
READ ACCESS PW2 or (PW1 and RWTBL2) or (PW1 and RTBL2)
WRITE ACCESS PW2 or (PW1 and RWTBL2)
A2h AND B2h MEMORY Common A2h and B2h memory locations
MEMORY TYPE Nonvolatile (SEE)
BCh RESERVED HLOS1
2
HLOS1
1
HLOS1
0
RESERVED LLOS1
2
LLOS1
1
LLOS1
0
BIT 7 BIT 0
This register controls the full-scale range of the QT monitoring for the RSSI1 differential inputs.
BITS 7, 3 RESERVED (default = 0)
BITS 6:4
HLOS1[2:0]: HLOS1 full-scale ranging: 3-bit value to select the full-scale comparison voltage for
high LOS found on RSSI1. Default is 000b and creates a full scale of 1.25V.
HLOS1[2:0] % OF 1.25V FS VOLTAGE (V)
000b 100.00 1.250
001b 80.02 1.0003
010b 66.69 0.8336
011b 50.05 0.6256
100b 40.05 0.5006
101b 33.38 0.4172
110b 28.62 0.3578
111b 25.04 0.313
BITS 2:0
LLOS1[2:0]: LLOS1 full-scale ranging: 3-bit value to select the full-scale comparison voltage for
low LOS found on RSSI1. Default is 000b and creates a full scale of 1.25V.
LLOS1[2:0] % OF 1.25V FS VOLTAGE (V)
000b 100.00 1.250
001b 80.02 1.0003
010b 66.69 0.8336
011b 50.05 0.6256
100b 40.05 0.5006
101b 33.38 0.4172
110b 28.62 0.3578
111b 25.04 0.313