Datasheet

53Maxim Integrated
SFP Controller for Dual Rx Interface
DS1877
Table 02h, Register B8h: LOS RANGING
2
FACTORY DEFAULT 00h
READ ACCESS PW2 or (PW1 and RWTBL2) or (PW1 and RTBL2)
WRITE ACCESS PW2 or (PW1 and RWTBL2)
A2h AND B2h MEMORY Common A2h and B2h memory location
MEMORY TYPE Nonvolatile (SEE)
B8h RESERVED HLOS2
2
HLOS2
1
HLOS2
0
RESERVED LLOS2
2
LLOS2
1
LLOS2
0
BIT 7 BIT 0
This register controls the full-scale range of the QT monitoring for the RSSI2 differential inputs.
BITS 7, 3 RESERVED (default = 0)
BITS 6:4
HLOS2[2:0]: HLOS2 full-scale ranging: 3-bit value to select the full-scale comparison voltage for
high LOS found on RSSI2. Default is 000b and creates a full scale of 1.25V.
HLOS2[2:0] % OF 1.25V FS VOLTAGE (V)
000b 100.00 1.250
001b 80.02 1.0003
010b 66.69 0.8336
011b 50.05 0.6256
100b 40.05 0.5006
101b 33.38 0.4172
110b 28.62 0.3578
111b 25.04 0.313
BITS 2:0
LLOS2[2:0]: LLOS2 full-scale ranging: 3-bit value to select the full-scale comparison voltage for
low LOS found on RSSI2. Default is 000b and creates a full scale of 1.25V.
LLOS2[2:0] % OF 1.25V FS VOLTAGE (V)
000b 100.00 1.250
001b 80.02 1.0003
010b 66.69 0.8336
011b 50.05 0.6256
100b 40.05 0.5006
101b 33.38 0.4172
110b 28.62 0.3578
111b 25.04 0.313