Datasheet
DS1822-PAR 
  8 of 19 
HARDWARE CONFIGURATION Figure 9 
TRANSACTION SEQUENCE 
The transaction sequence for accessing the DS1822-PAR is as follows: 
Step 1.  Initialization 
Step 2.  ROM Command (followed by any required data exchange) 
Step 3.  DS1822-PAR Function Command (followed by any required data exchange) 
It is very important to follow this sequence every time the DS1822-PAR is accessed, as the DS1822-PAR 
will not respond if any steps in the sequence are missing or out of order. Exceptions to this rule are the 
Search ROM [F0h] and Alarm Search [ECh] commands. After issuing either of these ROM commands, 
the master must return to Step 1 in the sequence. 
INITIALIZATION 
All transactions on the 1-Wire bus begin with an initialization sequence. The initialization sequence 
consists of a reset pulse transmitted by the bus master followed by presence pulse(s) transmitted by the 
slave(s). The presence pulse lets the bus master know that slave devices (such as the DS1822-PAR) are 
on the bus and are ready to operate. Timing for the reset and presence pulses is detailed in the 
1-WIRE SIGNALING section. 
ROM COMMANDS 
After the bus master has detected a presence pulse, it can issue a ROM command. These commands 
operate on the unique 64-bit ROM codes of each slave device and allow the master to single out a specific 
device if many are present on the 1-Wire bus. These commands also allow the master to determine how 
many and what types of devices are present on the bus or if any device has experienced an alarm 
condition. There are five ROM commands, and each command is eight bits long. The master device must 
issue an appropriate ROM command before issuing a DS1822-PAR function command. A flowchart for 
operation of the ROM commands is shown in Figure 10. 
SEARCH ROM [F0h] 
When a system is initially powered up, the master must identify the ROM codes of all slave devices on 
the bus, which allows the master to determine the number of slaves and their device types. The master 
V
PU
4.7k 
5μA
Typ.
R
X
T
X
DS1822-PAR 1-WIRE PORT
100Ω 
M
OS
FET
T
X
R
X
R
X
 = RECEIVE 
T
X
 = TRANSMIT 
1-wire bus 
DQ 
Pin 
V
PU
Micro-
processor 
Strong 
Pullup 