The DS1822-PAR samples the 1-Wire bus during a window that lasts from 15μs to 60μs after the master
initiates the write-time slot. If the bus is high during the sampling window, a 1 is written to the DS1822-
PAR. If the line is low, a 0 is written to the DS1822-PAR.
READ/WRITE-TIME SLOT TIMING DIAGRAM Figure 12
READ-TIME SLOTS
The DS1822-PAR can only transmit data to the master when the master issues read-time slots. Therefore,
the master must generate read-time slots immediately after issuing a Read Scratchpad [BEh] command,
so that the DS1822-PAR can provide the requested data. In addition, the master can generate read-time
slots after issuing a Recall E
2
[B8h] command to find out the recall status as explained in the DS1822-
PAR FUNCTION COMMAND section.
All read-time slots must be a minimum of 60 μs in duration with a minimum of a 1μs recovery time
between slots. A read-time slot is initiated by the master device pulling the 1-Wire bus low for a
minimum of μs and then releasing the bus (see Figure 12). After the master initiates the read-time slots,
the DS1822-PAR will begin transmitting a 1 or 0 on bus. The DS1822-PAR transmits a 1 by leaving the
bus high and transmits a 0 by pulling the bus low. When transmitting a 0, the DS1822-PAR will release
the bus by the end of the time slot, and the bus will be pulled back to its high idle state by the pullup
LINE TYPE LEGEND
Bus master pulling low DS1822-PAR pulling low
Resistor pullup
45μs
15μs
V
PU
GND
1-WIRE BUS
60μs < T
X
“0” < 120
μ
s
1μs < T
REC
<
∞
DS1822-PAR samples
MIN TYP MAX
15μs
30
μ
s
> 1
μ
s
MASTER WRITE “0” SLOT MASTER WRITE “1” SLOT
DS1822-PAR samples
MIN TYP MAX
V
PU
GND
1-WIRE BUS
15
μ
s
MASTER READ “0” SLOT MASTER READ “1” SLOT
Master samples
Master samples
START
OF SLOT
START
OF SLOT
> 1
μ
s
1 μs < T
REC
<
∞
15μs
15
μ
s
30μs
15
μ
s
> 1μs