Datasheet

DS1818
5 of 5
NOTES:
1. All voltages are referenced to ground.
2. Measured with V
CC
³ 2.7V.
3. A 1 kW external pull-up resistor may be required in some applications for proper operation of the
microprocessor reset control circuit.
4. Measured with RST output open.
5. Measured with 2.7V £ V
CC
£ 3.3V.
6. t
R
= 5 ms.
7. V
OH
and I
OH
are a function of the value of R
P
and the associated output load conditions.
8. The t
F
value is for reference in defining values for t
RPD
and should not be considered a requirement for
proper operation or use of the device.
PART MARKING CODES
“A”, “B”, &“C” represent the device type.
810 - DS1810
811 - DS1811
812 - DS1812
813 - DS1813
815 - DS1815
816 - DS1816
817 - DS1817
818 - DS1818
“D” represents the device tolerance.
A- 5%
B - 10%
C - 15%
D - 20%