Datasheet
DS1683
Total-Elapsed-Time and Event Recorder with Alarm
2Maxim Integrated
(All voltages referenced to GND.)
Voltage Range on V
CC
, ALARM, SDA, SCL ........-0.5V to +6.0V
Voltage Range on EVENT
........................ -0.5V to (V
CC
+ 0.5V),
not to exceed +6.0V
Continuous Power Dissipation (T
A
= +70NC)
SO (derate 5.9mW/NC above +70NC)
....................... 470.6mW
Maximum Junction Temperature
.....................................+150NC
Operating Temperature Range
.......................... -40NC to +85NC
Programming Temperature Range
....................... 0NC to +70NC
Storage Temperature Range
............................ -55NC to +150NC
Lead Temperature (soldering, 10s)
................................+300NC
Soldering Temperature (reflow)
......................................+260NC
ABSOLUTE MAXIMUM RATINGS
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional opera-
tion of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
(T
A
= -40NC to +85NC, unless otherwise noted.)
DC ELECTRICAL CHARACTERISTICS
(V
CC
= 2.5V to 5.5V, T
A
= -40NC to +85NC, unless otherwise noted.)
EVENT TIMING
(V
CC
= 2.5V to 5.5V, T
A
= -40NC to +85NC, unless otherwise noted.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Supply Voltage V
CC
(Note 1) 2.5 5.5 V
Input Logic 1 (SCL, SDA) V
IH
0.7 x V
CC
V
CC
+ 0.3 V
Input Logic 0 (SCL, SDA) V
IL
-0.3 0.3 x V
CC
V
EVENT Input Trip Point V
ETP
0.3 x
V
CC
0.5 x
V
CC
0.7 x
V
CC
V
EVENT Trip Point Hysteresis V
HYS
1% of V
CC
Power-On Reset V
POR
2.4 V
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Input Leakage I
LI
-1 +1
FA
ALARM Output (I
OL
= 10mA) V
OL
0.8 V
SDA Output (I
OL
= 4mA) V
OL
0.4 V
Active Supply Current I
CCA
(Note 1) 180 300
FA
EEPROM Write Current I
EE
(Note 1) 250 350
FA
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Time Event Minimum t
G
(Note 1) 10 35 70 ms
Time Event Increment t
EI
(Note 1) 237.5 250 262.5 ms
Time Event Max t
EM
(Note 2) 34 Years
CLR ALM to Alarm Set (Note 2) 10 150
Fs