Datasheet

Voltage Range on Any Pin Relative to Ground ......-0.3V to +6V
Operating Temperature Range
........................... -40°C to +85°C
Storage Temperature Range
............................ -55°C to +125°C
Lead Temperature (soldering, 10s)
.................................+300°C
Soldering Temperature (reflow)
....................................... +260°C
(T
A
= -40°C to +85°C, unless otherwise noted.)
(V
CC
= 2.5V to 5.5V, T
A
= -40°C to +85°C, unless otherwise noted.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Power-Supply Voltage V
CC
2.5 5.5 V
Input Trip Point V
ETP
0.3 x
V
CC
0.5 x
V
CC
0.7 x
V
CC
V
Event Trip-Point Hysteresis V
HYS
1% of
V
CC
%
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Input Leakage I
LI
-1 +1 µA
ALARM Output (I
OL
= 10mA)
V
OL
0.8 V
SDA Output (I
OL
= 4mA) V
OL
0.8 V
Active Supply Current
(Event Active)
I
CCA
(Note 1) 120 300 µA
Standby Current
(Event Active) (Note 1)
I
CCS
V
CC
= 5.5V 6 15
µA
V
CC
= 3.0V 2 4
EEPROM Write Current I
EE
(Note 1) 150 300 µA
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Time Event Minimum t
G
(Note 1) 10 35 70 ms
Time Event Start t
ES
(Note 1) 112 125 137 ms
Time Event Increment t
EI
(Note 1) 237.5 250 262.5 ms
Time Event Max t
EM
34 Years
DS1682 Total-Elapsed-Time Recorder
with Alarm
www.maximintegrated.com
Maxim Integrated
2
Absolute Maximum Ratings
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these
or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect
device reliability.
Recommended DC Operating Conditions
DC Electrical Characteristics
Event Timing
(V
CC
= 2.5V to 5.5V, T
A
= -40°C to +85°C, unless otherwise noted.)