Figure 8. Data Read: Slave Transmitter Mode
THERMAL INFORMATION
PACKAGE
THETA-JA
THETA-JC
8 PDIP (300 mils)
110°C/W
40°C/W
8 SO (150 mils)
128.4°C/W
36°C/W
8 µSOP (3mm)
206.3°C/W
42°C/W
PACKAGE INFORMATION
For the latest package outline information and land patterns (footprints), go to www.maxim-ic.com/packages. Note
that a “+”, “#”, or “-“ in the package code indicates RoHS status only. Package drawings may show a different suffix
character, but the drawing pertains to the package regardless of RoHS status.
PACKAGE TYPE PACKAGE CODE OUTLINE NO. LAND PATTERN NO.
8 PDIP (300 mils)
P8+1
21-0043
—
8 SO (150 mils)
S8+5
21-0041
90-0096
8 µSOP (3mm)
U8+1
21-0036
90-0092
AXXXXXXXXA1101000S 1 XXXXXXXX A XXXXXXXX A XXXXXXXX A P
<Slave Address> <Data(n)> <Data(n+1) <Data(n+2)> <Data(n+X)>
S - START
A - ACKNOWLEDGE
P - STOP
A - NOT ACKNOWLEDGE
<RW>
R/W - READ/WRITE OR DIRECTION BIT ADDRESS = D1H
DATA TRANSFERRED
(X+1 BYTES + ACKNOWLEDGE); NOTE: LAST DATA BYTE IS