Datasheet

DS1230W
9 of 10
DC TEST CONDITIONS AC TEST CONDITIONS
Outputs Open Output Load: 100pF + 1TTL Gate
Cycle = 200ns for operating current Input Pulse Levels: 0 to 2.7V
All voltages are referenced to ground Timing Measurement Reference Levels
Input: 1.5V
Output: 1.5V
Input pulse Rise and Fall Times: 5ns
ORDERING INFORMATION
PART TEMP RANGE
SUPPLY
TOLERANCE
PIN-PACKAGE
SPEED GRADE
(ns)
DS1230W-100+
0°C to +70°C
3.3V ± 0.3V
28 740 EDIP
100
DS1230WP-100+
0°C to +70°C
3.3V ± 0.3V
34 PowerCap*
100
DS1230W-100IND+
-40°C to +85°C
3.3V
±
0.3V
28 740 EDIP
100
DS1230WP-100IND+
-40°C to +85°C
3.3V ± 0.3V
34 PowerCap*
100
+Denotes a lead(Pb)-free/RoHS-compliant package.
*DS9034PC+ or DS9034PCI+ (PowerCap) required. Must be ordered separately.
PACKAGE INFORMATION
For the latest package outline information and land patterns, go to www.maxim-ic.com/packages. Note that a “+”,
#, or-” in the package code indicates RoHS status only. Package drawings may show a different suffix
character, but the drawing pertains to the package regardless of RoHS status.
PACKAGE TYPE PACKAGE CODE OUTLINE NO. LAND PATTERN NO.
28 EDIP MDT28+3
21-0245
34 PCAP PC2+4
21-0246