Instruction Manual
78M6612 M-API Library User Guide UG_6612_036
26 Rev. 1.00
Parameters SetData Input parameter.
TRUE(1) – Set calibration data as specified in MPU_CParms_t.
FALSE(0) – Get current calibration data and return values in MPU_CParms_t.
MAPI_CParams:
C_Tcal Input parameter – read-only. Calibration type. None(0x00).
C_Wcal Output parameter (SetData = FALSE), Input parameter (SetData = TRUE)
Referenced Wattage calibration value (in Watts). Default = 120W.
C_Vcal Output parameter (SetData = FALSE), Input parameter (SetData = TRUE)
Referenced Voltage calibration value (Vrms) . Default = 120V.
C_Ical Output parameter (SetData = FALSE), Input parameter (SetData = TRUE)
Referenced Current calibration value (Arms). Default = 1A.
C_Pcal Output parameter (SetData = FALSE), Input parameter (SetData = TRUE)
Referenced Phase calibration value (in 0.1 C Degrees). Default = 0 degree.
C_Wtolerance Output parameter (SetData = FALSE), Input parameter (SetData = TRUE).
Watts Tolerance (Watts). Default = 0.01W or 10mW.
C_Vtolerance Output parameter (SetData = FALSE), Input parameter (SetData = TRUE)
Voltage Tolerance (Vrms). Default = 10mV.
C_Itolerance Output parameter (SetData = FALSE), Input parameter (SetData = TRUE)
Current Tolerance (Arms). Default = 10mA.
C_Ptolerance Output parameter (SetData = FALSE), Input parameter (SetData = TRUE)
Phase Tolerance (degrees). Default = 0.1 Degree.
C_Vavg_cnt Output parameter (SetData = FALSE), Input parameter (SetData = TRUE)
Voltage Average count. Default = 3.
C_Iavg_cnt Output parameter (SetData = FALSE), Input parameter (SetData = TRUE)
Current Average count. Default = 3.
C_Wavg_cnt Output parameter (SetData = FALSE), Input parameter (SetData = TRUE)
Watts Average count. Default = 3.
C_Vmax_cnt Output parameter (SetData = FALSE), Input parameter (SetData = TRUE)
Maximum number of voltage reads to test for pass/fail result. Default = 10.
C_Imax_cnt Output parameter (SetData = FALSE), Input parameter (SetData = TRUE)
Maximum number of current reads to test for pass/fail result. Default = 10.
C_Wmax_cnt Output parameter (SetData = FALSE), Input parameter (SetData = TRUE)
Maximum number of Watts reads to test for pass/fail result. Default = 10.
C_Wrate_cal Output parameter.
Wrate use during calibration (~.32kh). Read-only.
C_Tempcal Output parameter (SetData = FALSE), Input parameter (SetData = TRUE).
Calibration temperature. In 0.1 degree unit.
Return Codes MAPI_OK //Calibration succeeded.
MAPI_ERROR //Calibration failed.
//For more detailed descriptions of the failure, call MAPI_CALStatus().